Wilo-FLA-2

Your advantages Sturdy system with 2 Helix FIRST V or MVI stainless steel high-pressure multistage centrifugal pumps, in accordance with DIN 1988 and DIN 14462 Absolute operational reliability for 2-pump systems with 100 % redundancy Easy adjustment and operational reliability due to the FLA control unit Pre-set throttle valve on the discharge side of the pump to protect the pump at low volume flows

Артикул Наименование Цена
2536592 FLA-2 MVI 7003/2 PN10 29529370
2536593 FLA-2 MVI 7003/1 PN10 29943470
2536594 FLA-2 MVI 7003 PN10 31004980
2536595 FLA-2 MVI 7004/2 PN10 32562400
2536596 FLA-2 MVI 7004/1 PN16 34481400
2536597 FLA-2 MVI 7004 PN16 35634315
2534433 FLA-2 Helix V 2204 PN10 16420075
2536598 FLA-2 MVI 7005/2 PN16 37951760
2534434 FLA-2 Helix V 2205 PN10 16897805
2536599 FLA-2 MVI 7005/1 PN16 38111845
2534435 FLA-2 Helix V 2206 PN16 17443205
2536600 FLA-2 MVI 7005 PN16 40182850
2534437 FLA-2 Helix V 2208 PN16 19366750
2536601 FLA-2 MVI 7006/2 PN16 40689870
2536591 FLA-2 MVI 7002 PN10 27547245
2536602 FLA-2 MVI 7006/1 PN16 42290215
2534403 FLA-2 Helix V 5203 PN10 23590570
2534382 FLA-2 Helix V 3603/2 PN10 18430480
2534404 FLA-2 Helix V 5204/2 PN10 25196470
2534383 FLA-2 Helix V 3603/1 PN10 19034965
2534405 FLA-2 Helix V 5204 PN16 25575725
2534385 FLA-2 Helix V 3604/2 PN10 20150005
2534406 FLA-2 Helix V 5205/2 PN16 26280705
2534386 FLA-2 Helix V 3604 PN16 20559055
2534407 FLA-2 Helix V 5205 PN16 27226065

Design

Pressure-boosting system for firefighting systems with indirect connection in accordance with DIN 14462.

With 2 vertical stainless steel high-pressure multistage centrifugal pumps in glanded version

Application

Fully automatic water supply for firefighting systems with wall hydrants of the type «F» in domestic, commercial and public buildings, hotels, hospitals, shopping centres and also offices and industrial buildings

Equipment/function

  • 2 Helix FIRST V 16, 22, 36, 52 or MVI 70 series pumps, equipped with IE2 motors
  • Automatic pump control via FLA control unit
  • Components that come in contact with the fluid are corrosion-resistant
  • Base frame made of galvanised steel, with height-adjustable vibration absorbers for insulation against structure-borne noise
  • Pipework made of 1.4301 stainless steel
  • Gear-operated shut-off ball cock or annular shut-off valve on the suction and pressure side of every pump
  • Non-return valve, pressure side
  • Throttle valve of stainless steel 1.4571 on the suction side of every pump
  • Pressure switch, on the pressure side
  • Pressure gauge, on the pressure side
  • Diaphragm pressure vessel 8 l, PN 16, on the pressure side
  • Accessories: Atmospherically ventilated break tank in accordance with DIN 14462 with free exhaust in accordance with EN 13077, type AB in accordance with DIN EN 1717

Typekey

Example:

Wilo- FLA — 2 Helix V 2204 PN10

FLA

Fire extinguishing system

2

Number of pumps

Helix V

Pump series

22

Rated volume flow [m3/h]

04

Number of pump stages

PN10

Pressure control up to 10 bar (pump type-dependent)

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Max. fluid temperature 50 °C
  • Operating pressure 10 or 16 bar
  • Inlet pressure from break tank < 1 bar
  • Nominal connection diameter on pressure side R 2″ - DN 125
  • Nominal connection diameter on suction side Rp 2" — DN 125
  • Operating unit protection class IP 54

Materials

  • Impellers, diffusers, stage housing made of stainless steel 1.4307
  • Pump housing made of EN-GJL-250, cataphoretically coated
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-Ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4301 stainless steel

Construction

  • Base frame: made of electrolytically galvanised steel and provided with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel 1.4301, suitable for the connection of all conventional piping materials; the pipework is dimensioned according to the overall hydraulic performance of the FLA pressure boosting system
  • Pumps: Helix FIRST V 16, 22, 36, 52 and MVI 70 series pumps; all pump components in contact with fluid are made of stainless steel/EN-GJL-250, with cataphoretic coating. For more information about the pump, please refer to the catalogue section «High-pressure multistage centrifugal pumps»
  • Valves: For each pump, the non-return valve has a 1.4571 needle-type throttle for returning the bypass volume flow to the break tank. All throttle valves and shut-off devices are sealed and protected against unauthorised adjustment. The pumps are equipped with an automatic air vent valve on the top of the hydraulics.
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side. For testing and inspection purposes, equipped with a special throughflow fitting that enables the diaphragm pressure vessel to be shut-off and drained
  • Pressure switch: A pressure switch arranged on the discharge side, for activation of the central FLA controller
  • Pressure indication: Pressure gauge (ø 63 mm) on the discharge side; additional digital display of operating pressure and setting parameters in the FLA controller
  • Control device/controller: The system is equipped with a specific FLA controller as standard

Scope of delivery

  • Factory-mounted, connection-ready pressure boosting system checked for functionality and impermeability
  • Packaging
  • Installation and operating instructions

Typekey

Example:

Wilo- FLA — 2 Helix V 2204 PN10

FLA

Fire extinguishing system

2

Number of pumps

Helix V

Pump series

22

Rated volume flow [m3/h]

04

Number of pump stages

PN10

Pressure control up to 10 bar (pump type-dependent)

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Max. fluid temperature 50 °C
  • Operating pressure 10 or 16 bar
  • Inlet pressure from break tank < 1 bar
  • Nominal connection diameter on pressure side R 2″ - DN 125
  • Nominal connection diameter on suction side Rp 2" — DN 125
  • Operating unit protection class IP 54

Materials

  • Impellers, diffusers, stage housing made of stainless steel 1.4307
  • Pump housing made of EN-GJL-250, cataphoretically coated
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-Ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4301 stainless steel

Construction

  • Base frame: made of electrolytically galvanised steel and provided with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel 1.4301, suitable for the connection of all conventional piping materials; the pipework is dimensioned according to the overall hydraulic performance of the FLA pressure boosting system
  • Pumps: Helix FIRST V 16, 22, 36, 52 and MVI 70 series pumps; all pump components in contact with fluid are made of stainless steel/EN-GJL-250, with cataphoretic coating. For more information about the pump, please refer to the catalogue section «High-pressure multistage centrifugal pumps»
  • Valves: For each pump, the non-return valve has a 1.4571 needle-type throttle for returning the bypass volume flow to the break tank. All throttle valves and shut-off devices are sealed and protected against unauthorised adjustment. The pumps are equipped with an automatic air vent valve on the top of the hydraulics.
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side. For testing and inspection purposes, equipped with a special throughflow fitting that enables the diaphragm pressure vessel to be shut-off and drained
  • Pressure switch: A pressure switch arranged on the discharge side, for activation of the central FLA controller
  • Pressure indication: Pressure gauge (ø 63 mm) on the discharge side; additional digital display of operating pressure and setting parameters in the FLA controller
  • Control device/controller: The system is equipped with a specific FLA controller as standard

Scope of delivery

  • Factory-mounted, connection-ready pressure boosting system checked for functionality and impermeability
  • Packaging
  • Installation and operating instructions