+7 (777) 777-88-87
Время работы ПН-ПТ с 09.00 до 18.00

Wilo-FLA-1

Your advantages Sturdy system with one Helix FIRST V or MVI stainless steel high-pressure multistage centrifugal pump, in accordance with DIN 1988 and DIN 14462 Absolute operational reliability Easy adjustment and operational reliability due to the FLA control unit Pre-set throttle valve on the discharge side of the pump to protect the pump at low volume flows

Артикул Наименование Цена
2536586 FLA-1 MVI 7005/1 PN16 17461385
2534432 FLA-1 Helix V 2208 PN16 9856085
2536587 FLA-1 MVI 7005 PN16 17764890
2536577 FLA-1 MVI 7002/1 PN10 11222110
2536588 FLA-1 MVI 7006/2 PN16 19377355
2536578 FLA-1 MVI 7002 PN10 11961430
2536589 FLA-1 MVI 7006/1 PN16 20242925
2536579 FLA-1 MVI 7003/2 PN10 13197165
2536580 FLA-1 MVI 7003/1 PN10 13397650
2536581 FLA-1 MVI 7003 PN10 13556725
2536582 FLA-1 MVI 7004/2 PN10 14517235
2536583 FLA-1 MVI 7004/1 PN16 15156060
2536584 FLA-1 MVI 7004 PN16 15682270
2536585 FLA-1 MVI 7005/2 PN16 17083645
2534420 FLA-1 Helix V 1605 PN10 5932235
2534431 FLA-1 Helix V 2207 PN16 9050105
2534378 FLA-1 Helix V 3606 PN16 10582275
2534421 FLA-1 Helix V 1606 PN10 6205440
2534368 FLA-1 Helix V 3602/1 PN10 8080000
2534392 FLA-1 Helix V 5202 PN10 9743975
2534422 FLA-1 Helix V 1607 PN10 7018490
2534369 FLA-1 Helix V 3602 PN10 8387545
2534393 FLA-1 Helix V 5203/2 PN10 10122725
2534423 FLA-1 Helix V 1608 PN16 7235640
2534370 FLA-1 Helix V 3603/2 PN10 8535005

Design

Pressure-boosting system for firefighting systems with indirect connection in accordance with DIN 14462.

With a vertical stainless steel high-pressure multistage centrifugal pump in glanded version

Application

Fully automatic water supply for firefighting systems with wall hydrants of the type «F» in domestic, commercial and public buildings, hotels, hospitals, shopping centres and also offices and industrial buildings

Equipment/function

  • A pump of the Helix FIRST V 16, 22, 36, 52 or MVI 70 series, equipped with IE3 motor
  • Automatic pump control via FLA control unit
  • Components that come in contact with the fluid are corrosion-resistant
  • Base frame made of galvanised steel, with height-adjustable vibration absorbers for insulation against structure-borne noise
  • Pipework made of 1.4301 stainless steel
  • Gear-operated ball valve or annular shut-off valve on the suction and discharge side of the pump
  • Non-return valve, on the discharge side
  • Throttle valve made of stainless steel 1.4571 on the suction side of the pump
  • Pressure switch, on the discharge side
  • Pressure gauge, on the discharge side
  • Diaphragm pressure vessel 8 l, PN 16, on the discharge side
  • Accessories: Atmospherically ventilated break tank in accordance with DIN 14462 with free exhaust in accordance with EN 13077, type AB in accordance with DIN EN 1717

Typekey

Example:

Wilo- FLA — 1 Helix V 2204 PN10

FLA

Fire extinguishing system

1

Number of pumps

Helix V

Pump series

22

Rated volume flow [m3/h]

04

Number of pump stages

PN10

Pressure control up to 10 bar (pump type-dependent)

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Max. fluid temperature 50 °C
  • Operating pressure 10 or 16 bar
  • Inlet pressure from break tank < 1 bar
  • Nominal connection diameter on pressure side R 2″ - DN 125
  • Nominal connection diameter on suction side Rp 2" — DN 125
  • Operating unit protection class IP 54

Materials

  • Impellers, diffusers, stage housing made of stainless steel 1.4307
  • Pump housing made of EN-GJL-250, cataphoretically coated
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-Ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4301 stainless steel

Construction

  • Base frame: made of electrolytically galvanised steel and provided with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel 1.4301, suitable for the connection of all conventional piping materials; the pipework is dimensioned according to the overall hydraulic performance of the FLA pressure boosting system
  • Pumps: Helix FIRST V 16, 22, 36, 52 and MVI 70 series pump; all pump components in contact with fluid are made of stainless steel/EN-GJL-250, with cataphoretic coating. For more information about the pump, please refer to the catalogue section «High-pressure multistage centrifugal pumps»
  • Valves: For each pump, the non-return valve has a 1.4571 needle-type throttle for returning the bypass volume flow to the break tank. All throttle valves and shut-off devices are sealed and protected against unauthorised adjustment. The pump is equipped with an automatic air vent valve on the top of the hydraulics.
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side. For testing and inspection purposes, equipped with a special throughflow fitting that enables the diaphragm pressure vessel to be shut-off and drained
  • Pressure switch: A pressure switch arranged on the discharge side, for activation of the central FLA controller
  • Pressure indication: Pressure gauge (ø 63 mm) on the discharge side; additional digital display of operating pressure and setting parameters in the FLA controller
  • Control device/controller: The system is equipped with a specific FLA controller as standard

Scope of delivery

  • Factory-mounted, connection-ready pressure boosting system checked for functionality and impermeability
  • Installation and operating instructions

Typekey

Example:

Wilo- FLA — 1 Helix V 2204 PN10

FLA

Fire extinguishing system

1

Number of pumps

Helix V

Pump series

22

Rated volume flow [m3/h]

04

Number of pump stages

PN10

Pressure control up to 10 bar (pump type-dependent)

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Max. fluid temperature 50 °C
  • Operating pressure 10 or 16 bar
  • Inlet pressure from break tank < 1 bar
  • Nominal connection diameter on pressure side R 2″ - DN 125
  • Nominal connection diameter on suction side Rp 2" — DN 125
  • Operating unit protection class IP 54

Materials

  • Impellers, diffusers, stage housing made of stainless steel 1.4307
  • Pump housing made of EN-GJL-250, cataphoretically coated
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-Ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4301 stainless steel

Construction

  • Base frame: made of electrolytically galvanised steel and provided with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel 1.4301, suitable for the connection of all conventional piping materials; the pipework is dimensioned according to the overall hydraulic performance of the FLA pressure boosting system
  • Pumps: Helix FIRST V 16, 22, 36, 52 and MVI 70 series pump; all pump components in contact with fluid are made of stainless steel/EN-GJL-250, with cataphoretic coating. For more information about the pump, please refer to the catalogue section «High-pressure multistage centrifugal pumps»
  • Valves: For each pump, the non-return valve has a 1.4571 needle-type throttle for returning the bypass volume flow to the break tank. All throttle valves and shut-off devices are sealed and protected against unauthorised adjustment. The pump is equipped with an automatic air vent valve on the top of the hydraulics.
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side. For testing and inspection purposes, equipped with a special throughflow fitting that enables the diaphragm pressure vessel to be shut-off and drained
  • Pressure switch: A pressure switch arranged on the discharge side, for activation of the central FLA controller
  • Pressure indication: Pressure gauge (ø 63 mm) on the discharge side; additional digital display of operating pressure and setting parameters in the FLA controller
  • Control device/controller: The system is equipped with a specific FLA controller as standard

Scope of delivery

  • Factory-mounted, connection-ready pressure boosting system checked for functionality and impermeability
  • Installation and operating instructions