Your advantages IE3 IEC three-phase AC motor (>= 0.75 kW) Impellers and stage housing made of stainless steel Pump housing made of EN-GJL-250 cast iron, KTL coating Single-phase and three-phase versions available Recommended services Maintenance Commissioning WiloCare

Артикул Наименование Цена
4210653 Economy MHIL 306 (3~400 V) Цена по запросу
4210656 Economy MHIL 504 (3~400 V) Цена по запросу
4210659 Economy MHIL 505 (3~400 V) Цена по запросу
4210662 Economy MHIL 506 (3~400 V) Цена по запросу
4210665 Economy MHIL 902 (3~400 V) Цена по запросу
4210667 Economy MHIL 903 (3~400 V) Цена по запросу
4210669 Economy MHIL 904 (3~400 V) Цена по запросу
4210671 Economy MHIL 905 (3~400 V) Цена по запросу
4210650 Economy MHIL 305 (3~400 V) Цена по запросу
4083904 Economy MHIL 502 (1~230 V) Цена по запросу
4083892 Economy MHIL 107 (3~400 V) Цена по запросу
4083905 Economy MHIL 502 (3~400 V) Цена по запросу
4083882 Economy MHIL 102 (3~400 V) Цена по запросу
4083893 Economy MHIL 107 (1~230 V) Цена по запросу
4083906 Economy MHIL 503 (1~230 V) Цена по запросу
4083883 Economy MHIL 102 (1~230 V) Цена по запросу
4083894 Economy MHIL 302 (1~230 V) Цена по запросу
4083907 Economy MHIL 503 (3~400 V) Цена по запросу
4083884 Economy MHIL 103 (3~400 V) Цена по запросу
4083895 Economy MHIL 302 (3~400 V) Цена по запросу
4083908 Economy MHIL 504 (1~230 V) Цена по запросу
4083885 Economy MHIL 103 (1~230 V) Цена по запросу
4083896 Economy MHIL 303 (1~230 V) Цена по запросу
4083910 Economy MHIL 505 (1~230 V) Цена по запросу
4083886 Economy MHIL 104 (3~400 V) Цена по запросу

Design

Non-self-priming multistage pump

Application

  • Water supply and pressure boosting
  • Industrial circulation systems
  • Process water
  • Closed cooling circuits
  • Washing systems
  • Irrigation
  • Water treatment

Equipment/function

  • Pump in monobloc design
  • Threaded connection
  • Single-phase or three-phase motor
  • Single-phase AC motor with integrated thermal motor protection

Typekey

Example:

MHIL 302-E-3-400-50-2-IE3

MHIL

Multistage horizontal high-pressure centrifugal pump

3

Flow rate in m3/h

02

Number of impellers

E

Gasket typeE = EPDMV = FKM (Viton)

3

1 = 1~ (alternating current)3 = 3~ (three-phase current)

400

Connection voltage in V

50

Frequency in Hz

2

Number of poles

IE3

IE3 motor

Technical data

  • Mains connection 1~230 V (+-10 %), 50 Hz or optionally 220 V (+-10 %), 60 Hz
  • Mains connection 3~230 V (+-10 %), 50 Hz (Δ) or optionally 220 V (+-10 %), 50 Hz (Δ), 400 V (+-10 %), 50 Hz (Y) or optionally 460 V (+-10 %), 60 Hz (Y)
  • Fluid temperature of -15 to +90 °C
  • Max. operating pressure 10 bar
  • Max. inlet pressure of 6 bar
  • Protection class 1~: IP X4; 3~: IP 54
  • Nominal diameters of pipe connections on pressure side: Rp 1 or Rp 1 1/4, depending on type
  • Nominal diameters of pipe connections on suction side Rp 1, Rp 1 1/4 or Rp 1 1/2, depending on type

Materials

  • Impellers of stainless steel 1.4301
  • Stage chambers made of 1.4301 stainless steel
  • Shaft of stainless steel 1.4301 (AISI 304) or 1.4057 (AISI 431 L)
  • EPDM seal
  • Housing cover EN-GJL-250 (cataphoretic-coated)
  • Lower housing section EN-GJL-250 (cataphoretic-coated)
  • Mechanical seal made of SiC/carbon
  • Bearing of tungsten carbide
  • Pump support foot EN-GJL-250 (cataphoretic-coated)

Scope of delivery

  • Pump
  • Installation and operating instructions

Typekey

Example:

MHIL 302-E-3-400-50-2-IE3

MHIL

Multistage horizontal high-pressure centrifugal pump

3

Flow rate in m3/h

02

Number of impellers

E

Gasket typeE = EPDMV = FKM (Viton)

3

1 = 1~ (alternating current)3 = 3~ (three-phase current)

400

Connection voltage in V

50

Frequency in Hz

2

Number of poles

IE3

IE3 motor

Technical data

  • Mains connection 1~230 V (+-10 %), 50 Hz or optionally 220 V (+-10 %), 60 Hz
  • Mains connection 3~230 V (+-10 %), 50 Hz (Δ) or optionally 220 V (+-10 %), 50 Hz (Δ), 400 V (+-10 %), 50 Hz (Y) or optionally 460 V (+-10 %), 60 Hz (Y)
  • Fluid temperature of -15 to +90 °C
  • Max. operating pressure 10 bar
  • Max. inlet pressure of 6 bar
  • Protection class 1~: IP X4; 3~: IP 54
  • Nominal diameters of pipe connections on pressure side: Rp 1 or Rp 1 1/4, depending on type
  • Nominal diameters of pipe connections on suction side Rp 1, Rp 1 1/4 or Rp 1 1/2, depending on type

Materials

  • Impellers of stainless steel 1.4301
  • Stage chambers made of 1.4301 stainless steel
  • Shaft of stainless steel 1.4301 (AISI 304) or 1.4057 (AISI 431 L)
  • EPDM seal
  • Housing cover EN-GJL-250 (cataphoretic-coated)
  • Lower housing section EN-GJL-250 (cataphoretic-coated)
  • Mechanical seal made of SiC/carbon
  • Bearing of tungsten carbide
  • Pump support foot EN-GJL-250 (cataphoretic-coated)

Scope of delivery

  • Pump
  • Installation and operating instructions