+7 (777) 777-88-87
Время работы ПН-ПТ с 09.00 до 18.00

SiFire-EN-100/315-296-145DJ

Производитель
Wilo
Артикул
4241674
47527570

Pressure boosting system as a fully automatic compact unit for fire fighting purposes in accordance with EN 12845.

Consisting of a pump with horizontal base frame — EN 733 — with spacer coupling, diesel motor and multistage vertical electric jockey pump, diaphragm pressure vessel (capacity: 20 l) and one switch cabinet per pump, fixed to a robust support structure.

Model SC-Fire D for the diesel motor, equipped with Smart Controller, plus model SC-Fire J for the jockey pump, solid construction made of special profiled parts with cut-outs for forklift trucks and hooks to ensure trouble-free, safe transportation. Height-adjustable bracket for the outlet manifold, special base plate for the diesel motor which reduces the transfer of vibrations considerably and increases the reliability and service life.

A circuit with dual pressure switch, pressure gauge, non-return valve, valve (secured from use by unauthorised personnel) for the main pump for automatic start. The cables are concealed in the construction and protected against bumps and cuts. Equipped with a diaphragm installed directly on the main pump housing as standard, to prevent overheating in the event of zero flow.

Fuel tank with level sensor and sufficient volume for six hours of autonomous operation, as well as 2 batteries on the base frame and battery charging units on the SC-Fire switch cabinet.

Independent anti-vibration base frame for the diesel motor pump.

Switchgears SC-Fire D and SC-Fire J for fire extinguishing systems in accordance with EN 12845.

Switchgears integrated in a sheet metal enclosure in accordance with protection class IP54.

Very high quality control system and particularly easy operation thanks to SC Fire control, with symbol-based LC display, simple user interface with clear menu layout, pressure and rotary switches for quick adjustment of parameters. Communicative controller for monitoring system operation.

The system has been mounted on the base frame with wires and pipes are ready for connection.

Inlet pressure:

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum pumping head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For the main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 750 m³/h (208 l/s) system configuration for the main pump.

Switchgears/control devices for fire water supply systems

Wilo-Control SC-Fire D (main pump with diesel motor)

Hardware:

Fully electronic central control unit, installed in a painted steel enclosure, protection class IP54, control and display devices on the front door

Features and functions:

The design of the control device depends on the power of the connected pump. The device comprises the following components:

  • Main switch: For switching the switchgear on and off. (For unauthorised use in the event of a fire)
  • Display: Display built into the door of the switch cabinet for operation and display purposes. Shows the operating data and the operating status of the pump and controller through a combination of symbols and numerical codes. Menu selection and parameter input is effected via the red button
  • Microprocessor with Soft PLC: Microprocessor PLC (Soft PLC), realised through programming, the power supply unit and the I/O wiring. The programming configuration depends on the system and the sprinkler system
  • Indicators: Longlife signal lamps which indicate the following: Operational readiness of the pump, operation of the pump, activation of the pressure switch, activation of the float switch, deactivation of the automatic mode, deactivation of the motor heater, temperature alarm, oil pressure alarm, false start, belt alarm, low fuel level, collective errors, manual stop
  • Buttons: Push button for manual stop, start battery A, start battery B, the lamp test and acknowledgement of alarms and warning messages
  • Fuse protection: Protective fuses for heating and battery charging unit in the switch cabinet
  • Motor startup: Automatic starting sequence with 6 start attempts via two alternating batteries or directly via the start button on the front panel
  • Motor protection: Monitoring of typical operating parameters of the diesel motor (temperature, oil pressure, etc.) without stopping
  • Monitoring of the water supply: By means of a float switch to ensure a minimum water level of 2/3 of the supply tank is always maintained
  • Monitoring of the power supply: Error message from the battery charging unit in the event of a failure of the power supply
  • Combined signal report: All types of error are displayed via a common error indicator
  • Individual signal report: Important individual errors are indicated via individual error indicators
  • Error message and acknowledgement: All error messages are displayed via LEDs, shown in the display as an error code and must be acknowledged

Software:

  • Factory-programmed for fully automatic operation
  • Information regarding motor speed, charging voltage and charging current.
  • Menu navigation with symbol representation

Conforms to the following standards:

  • Fixed Firefighting Systems — Automatic Sprinkler Systems — (EN 12845), part for pumps with diesel motor
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC — Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC — Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo SC-Fire D control devices can be used to control pumps with a diesel motor, sensors for pump management and the level of information. The SC-unit is controlled via a microprocessor with Soft PLC. It is used to control and regulate the necessary functions of pressure boosting systems for fire fighting in accordance with EN 12845 for test purposes and operation of the sprinkler system.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

If a large amount of water is requested due to the opening of one or more circuits or due to a defective sprinkler, the pressure in the system decreases. The SC-Fire controller then initiates a startup of the diesel motor pump. As soon as the sprinkler circuit or gate valve via which the sprinkler heads are supplied is closed, holding pressure (resting pressure) is built up in the system. The stop buttons on the SC-Fire must then be actuated to stop the main pump.

Additional information:

A significant advantage offered by the Smart Controller SC-Fire is the user friendliness of the tried and tested Wilo red-button technology. At the heart of the SC is the Soft PLC programmable logic controller, which is based exclusively on Wilo's wealth of experience. All programming is implemented internally. These next generation control devices can therefore be used flexibly and fulfil customer-specific requirements in all markets.

Wilo-Control SC-Fire J (jockey pump with electric motor)

Hardware:

Fully electromechanical control unit, installed in a painted steel enclosure, protection class IP54, control devices and buttons on the front door

Features and functions:

The design of the control device depends on the power of the connected pump. The device comprises the following components:

  • Main switch: For switching the switchgear on and off
  • Indicators: Longlife signal lamps, which indicate the operational readiness of the pump, operation of the pump and collective errors
  • Switches: Rotary switch for setting the manual mode or automatic mode
  • Motor startup: Direct contactor
  • Motor protection: Switch for protection against short-circuits and overloads
  • Individual signal report: Motor error message (short-circuit, overload)
  • Error message and acknowledgement: The motor error message is indicated via corresponding LEDs. The error is acknowledged when the motor protection switch is restarted

Conforms to the following standards:

  • Fixed Firefighting Systems — Automatic Sprinkler Systems — (EN 12845), part for jockey pumps
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC — Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC — Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo-Control SC-Fire J units can be used to control jockey pumps with an electric motor and sensors according to EN 12845, as well as for test purposes and operation of the sprinkler system.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump, which is used for pressure boosting, is started first and ensures that the system is filled with water and that it remains pressurised. It is activated in the event of a pressure drop in the system. A properly calibrated pressure switch is used for controlled starting and stopping procedures.

Diesel engine
Air volume flow cooling
730 m³/h
Cylinder number
Cylinder capacity
4.5 l 
Cooling method
Air 
Rated power
144500 W
Rated speed
2900 1/min
Product data
Product description
SiFire-EN-100/315-296-145DJ 
EAN number
4062679084206 
Date of sales availability
2020-09-20 
Brand
Wilo 
Minimum order quantity
Colour
Red/black/silver 
Article number
4241674 
Installation dimensions
Pipe connection on the suction side
DN 125 
Pipe connection on the discharge side
DN 150 
Materials
Pump housing
Ductile cast iron 
Pipework material
Steel 
Gasket material
EPDM 
Shaft
Stainless steel 
Packaging
Number per layer
Pieces per pallet
Packaging property
Sales packaging 
Packaging type
Special pallet 
Hydraulic data
Max. ambient temperature
40 °C
Maximum operating pressure
16 bar
Min. fluid temperature
3 °C
Maximum inlet pressure
6 bar
Min. ambient temperature
10 °C
Max. fluid temperature
50 °C
Number of pumps
Dimension, weight
Length with packaging
1782 mm
Width with packaging
2878 mm
Net weight, approx.
1595 kg
Height
2445 mm
Width
2678 mm
Height with packaging
2575 mm
Gross weight, approx.
1625 kg
Length
1582 mm
Motor data
Protection class switchgear
IP54 
Артикул Название Цена
4241564 SiFire-EN-65/200-195-26,5D 21190810
4241596 SiFire-EN-100/250-267-109D 36294855
4241575 SiFire-EN-65/315-330-100D 40073265
4241609 SiFire-EN-32/200-191-10,5DJ 18811755
4241586 SiFire-EN-80/315-275-100D 38829955
4241565 SiFire-EN-65/200-207-26,5D 22449270
4241597 SiFire-EN-100/250-280-145D 38471405
4241576 SiFire-EN-80/200-185-26,5D 22933060
4241610 SiFire-EN-32/200-200-10,5DJ 19437955
4241587 SiFire-EN-80/315-290-109D 40480800
4241566 SiFire-EN-65/200-214-31,5D 24195055
4241598 SiFire-EN-100/315-285-145D 45097005
4241577 SiFire-EN-80/200-195-26,5D 23129000
4241611 SiFire-EN-32/250-198-6,8DJ 18175455
4241556 SiFire-EN-50/200-218-26,5D 22058400
4241522 SiFire-EN-100/250-280-132EJ 32132140
4241535 SiFire-EN-32/200-200-10,5D 18856700
4241546 SiFire-EN-40/250-244-26,5D 23142635
4241512 SiFire-EN-80/315-290-110EJ 36666030
4241557 SiFire-EN-50/250-220-17,7D 20327765
4241523 SiFire-EN-100/315-285-132EJ 38580485
4241536 SiFire-EN-32/250-198-6,8D 18491585
4241547 SiFire-EN-40/250-250-26,5D 23313325
4241513 SiFire-EN-80/315-308-132EJ 35203550
4241558 SiFire-EN-50/250-240-26,5D 22625515