+7 (777) 777-88-87
Время работы ПН-ПТ с 09.00 до 18.00

SiFire-EN-50/160-155-7,5EJ

Производитель
Wilo
Артикул
4241474
10898910

Pressure boosting system as a fully automatic compact unit for fire fighting purposes in accordance with EN 12845.

Consisting of a main pump with horizontal base frame — EN 733 — with spacer coupling, electric motor and multistage vertical electric jockey pump, diaphragm pressure vessel (capacity: 20 l) and one switch cabinet per pump, fixed to a robust support structure.

Model SC-Fire E for the electric motor, equipped with Smart Controller, plus model SC-Fire J for the jockey pump, solid construction made of special profiled parts with cut-outs for forklift trucks and hooks to ensure trouble-free, safe transportation. Height-adjustable bracket for the outlet manifold and special base plate which reduces the transfer of vibrations considerably and increases the reliability and service life.

A circuit with dual pressure switch, pressure gauge, non-return valve, valve (secured from use by unauthorised personnel) for the main pump for automatic start. The cables are concealed in the construction and protected against bumps and cuts. Equipped with a diaphragm installed directly on the main pump housing as standard, to prevent overheating in the event of zero flow.

Switchgears SC-Fire E and SC-Fire J for fire extinguishing systems in accordance with EN 12845.

Switchgears integrated in a sheet metal enclosure in accordance with protection class IP54.

Very high quality control system and particularly easy operation thanks to SC Fire control, with symbol-based LC display, simple user interface with clear menu layout, pressure and rotary switches for quick adjustment of parameters. Communicative controller for monitoring system operation.

The system has been mounted on the base frame with wires and pipes are ready for connection.

Inlet pressure:

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum pumping head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For the main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 750 m³/h (208 l/s) system configuration for the main pump.

Switchgears/control devices for fire water supply systems

Wilo-Control SC-Fire E (main pump with electric motor)

Hardware:

Fully electronic central control unit, installed in a painted steel enclosure, protection class IP54, control and display devices on the front door

Features and functions:

The design of the control device depends on the power of the connected pump (start via DOL or star-delta connection). The device comprises the following components:

  • Main switch: For switching the switchgear on and off. (For unauthorised use in the event of a fire)
  • Display: Display built into the door of the switch cabinet for operation and display purposes. Shows the operating data and the operating status of the pump and controller through a combination of symbols and numerical codes. Menu selection and parameter input is effected via the red button
  • Microprocessor with Soft PLC: Microprocessor PLC (Soft PLC), realised through programming, the power supply unit and the I/O wiring. The programming configuration depends on the system and the sprinkler system
  • Indicators: Longlife signal lamps indicate the operational readiness and operation of the pump, the activation of the pressure switch and the float switch, a false start, a collective error, manual start and manual stop
  • Buttons: Push buttons for manual start and manual stop, the lamp test and acknowledgement of alarms and warning messages
  • Fuse protection: Fuses which tolerate the starting current for at least 20 s
  • Motor startup: Contactor for direct-on-line starting, up to 22 kW, for higher power levels start via star-delta connection
  • Motor protection: Only for signalling
  • Monitoring of the water supply: By means of a float switch to ensure a minimum water level of 2/3 of the supply tank is always maintained
  • Performance monitoring: Power supply and performance of the pump
  • Combined signal report: All types of error are displayed via a common error indicator
  • Individual signal report: The important false start error message is displayed via an individual error indicator
  • Error message and acknowledgement: All error messages are displayed via LEDs, shown in the display as an error code and must be acknowledged

Software:

  • Factory-programmed for fully automatic operation
  • Information regarding voltage, electric current and power of the pump
  • Menu navigation with symbol representation

Conforms to the following standards:

  • Fixed Firefighting Systems — Automatic Sprinkler Systems — (EN 12845), part for pumps with electric motor
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC — Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC — Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo SC-Fire E control devices can be used to control pumps with an electric motor, sensors for pump management and the level of information. The SC-unit is controlled via a microprocessor with Soft PLC. It is used to control and regulate the necessary functions of pressure boosting systems for fire fighting in accordance with EN 12845 for test purposes and operation of the sprinkler system.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

If a large amount of water is requested due to the opening of one or more circuits or due to a defective sprinkler, the pressure in the system decreases. The SC-Fire controller then initiates a startup of the main pump. As soon as the sprinkler circuit or gate valve via which the sprinkler heads are supplied is closed, holding pressure (resting pressure) is built up in the system. The stop buttons on the SC-Fire must then be actuated to stop the main pump.

Additional information:

A significant advantage offered by the Smart Controller SC-Fire is the user friendliness of the tried and tested Wilo red-button technology. At the heart of the SC is the Soft PLC programmable logic controller, which is based exclusively on Wilo's wealth of experience. All programming is implemented internally. These next generation control devices can therefore be used flexibly and fulfil customer-specific requirements in all markets.

Wilo-Control SC-Fire J (jockey pump with electric motor)

Hardware:

Fully electromechanical control unit, installed in a painted steel enclosure, protection class IP54, control devices and buttons on the front door

Features and functions:

The design of the control device depends on the power of the connected pump. The device comprises the following components:

  • Main switch: For switching the switchgear on and off
  • Indicators: Longlife signal lamps, which indicate the operational readiness of the pump, operation of the pump and collective errors
  • Switches: Rotary switch for setting the manual mode or automatic mode
  • Motor startup: Direct contactor
  • Motor protection: Switch for protection against short-circuits and overloads
  • Individual signal report: Motor error message (short-circuit, overload)
  • Error message and acknowledgement: The motor error message is indicated via corresponding LEDs. The error is acknowledged when the motor protection switch is restarted

Conforms to the following standards:

  • Fixed Firefighting Systems — Automatic Sprinkler Systems — (EN 12845), part for jockey pumps
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC — Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC — Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo-Control SC-Fire J units can be used to control jockey pumps with an electric motor and sensors according to EN 12845, as well as for test purposes and operation of the sprinkler system.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump, which is used for pressure boosting, is started first and ensures that the system is filled with water and that it remains pressurised. It is activated in the event of a pressure drop in the system. A properly calibrated pressure switch is used for controlled starting and stopping procedures.

Hydraulic data
Maximum operating pressure
16 bar
Min. fluid temperature
3 °C
Number of pumps
Maximum inlet pressure
6 bar
Max. ambient temperature
40 °C
Min. ambient temperature
4 °C
Max. fluid temperature
50 °C
Packaging
Number per layer
Pieces per pallet
Packaging property
Sales packaging 
Packaging type
Special pallet 
Product data
Minimum order quantity
EAN number
4062679082202 
Colour
Red/black/silver 
Product description
SiFire-EN-50/160-155-7,5EJ 
Article number
4241474 
Date of sales availability
2020-09-20 
Brand
Wilo 
Dimension, weight
Gross weight, approx.
564 kg
Height with packaging
1600 mm
Length
1026 mm
Height
1470 mm
Width with packaging
1748 mm
Net weight, approx.
534 kg
Length with packaging
1226 mm
Width
1548 mm
Materials
Shaft
Stainless steel 
Pump housing
Grey cast iron 
Gasket material
EPDM 
Pipework material
Steel 
Motor data
Rated current
13.5 A
Protection class switchgear
IP54 
Power factor
0.88 
Rated speed
2900 1/min
Mains connection
3~400 V, 50 Hz 
Rated power
7.5 kW 
Installation dimensions
Pipe connection on the suction side
DN 65 
Pipe connection on the discharge side
DN 80 
Артикул Название Цена
4241619 SiFire-EN-40/250-218-17,7DJ 22457855
4241662 SiFire-EN-80/315-290-109DJ 42779055
4241630 SiFire-EN-50/200-210-17,7DJ 21339785
4241641 SiFire-EN-65/200-214-31,5DJ 25970635
4241652 SiFire-EN-80/200-195-26,5DJ 24706620
4241620 SiFire-EN-40/250-226-17,7DJ 22486640
4241663 SiFire-EN-80/315-308-145DJ 46194370
4241631 SiFire-EN-50/200-218-26,5DJ 23966795
4241642 SiFire-EN-65/200-226-37DJ 26582695
4241653 SiFire-EN-80/200-201-31,5DJ 27228590
4241621 SiFire-EN-40/250-244-26,5DJ 25215660
4241664 SiFire-EN-80/315-318-145DJ 47204370
4241632 SiFire-EN-50/250-220-17,7DJ 21733180
4241643 SiFire-EN-65/250-226-31,5DJ 26275655
4241588 SiFire-EN-80/315-308-145D 44529385
4241567 SiFire-EN-65/200-226-37D 24822265
4241599 SiFire-EN-100/315-296-145D 45541910
4241578 SiFire-EN-80/200-201-31,5D 25480280
4241612 SiFire-EN-32/250-222-10,5DJ 19785900
4241589 SiFire-EN-80/315-318-145D 44910660
4241568 SiFire-EN-65/250-226-31,5D 24548050
4241600 SiFire-EN-100/315-302-197D 59346085
4241579 SiFire-EN-80/200-210-37D 26809945
4241613 SiFire-EN-32/250-234-12,9DJ 20368670
4241590 SiFire-EN-80/315-324-197D 51870065